60kW 75kVA Cummins 4BTA3.9-G2 Silent Diesel Generator Set

60kW 75kVA Cummins 4BTA3.9-G2 Silent Diesel Generator Set

Share to:

Description

Core Specifications

This HONGTAI 60kW silent diesel generator set is configured for 60Hz, 220V, 3 phase power supply. It uses a Cummins 4BTA3.9-G2 diesel engine and an AVR-controlled TFW2-50 brushless alternator. The key electrical values below are taken from the supplied alternator nameplate.

ProductHONGTAI 60kW 75kVA Cummins Silent Diesel Generator Set
Prime Power60kW / 75kVA
Standby Power66kW / 82.5kVA
EngineCummins 4BTA3.9-G2
AlternatorTFW2-50 brushless AC alternator, AVR controlled
Frequency / Speed60Hz / 1800 rpm
Rated Voltage220V
Phase3 phase
Power Factor0.8
Rated Current196.8A
Duty RatingS1 continuous duty
EnclosureWeather-protected sound-attenuated silent canopy
ATSOptional

Nameplate verification: the supplied alternator nameplate states TFW2-50, 75kVA, 60Hz, 220V, 3 phase, 0.8 power factor, 196.8A and 1800 rpm. It does not display a Stamford brand name. This page therefore accurately describes the supplied unit as a TFW2-50 AVR-controlled brushless alternator.

Product Overview

The HONGTAI 60kW / 75kVA Cummins silent diesel generator set is designed for 60Hz, 220V, three-phase power applications. Powered by a Cummins 4BTA3.9-G2 industrial diesel engine and paired with an AVR-controlled brushless alternator, it provides practical standby power and suitably specified prime power for commercial, industrial and project applications.

The sound-attenuated canopy provides weather protection, maintenance access and a more controlled operating environment for outdoor installations. ATS, fuel-tank, remote-monitoring and canopy options can be configured to match the actual project.

Cummins 4BTA3.9-G2 Engine Specifications

ManufacturerCummins
Engine Model4BTA3.9-G2
Engine Type4-stroke, in-line, 4-cylinder diesel engine
Displacement3.9L
Bore × Stroke102mm × 120mm
Compression Ratio17.3:1
Cooling SystemWater-cooled
Air IntakeTurbocharged and aftercooled
Fuel SystemDirect injection diesel fuel system
Rated Speed1800 rpm for this 60Hz configuration

Engine Output & Fuel Use

  • Generator-set prime output: 60kW / 75kVA
  • Generator-set standby output: 66kW / 82.5kVA
  • Typical fuel use at full rated 60kW load: approximately 17L/h
  • Typical fuel use at 75% load: approximately 13L/h
  • Typical fuel use at 50% load: approximately 9L/h

Fuel consumption is affected by load, ambient temperature, altitude, fuel quality and installed accessories. Use the final approved data sheet for contractual fuel-consumption values.

TFW2-50 Brushless Alternator Specifications

The supplied alternator is an AVR-controlled AC generator. The values below are read from the supplied alternator nameplate.

Alternator TypeTFW2-50
Rated Power75kVA
Rated Voltage220V
Frequency60Hz
Rated Speed1800 rpm
Phase3 phase
Power Factor0.8
Rated Current196.8A
DutyS1 continuous duty
AVR8A
Excitation Voltage / Current55V / 2.2A
Insulation ClassH
Protection ClassIP23
Ambient Temperature40°C
Manufacturing DateApril 2023

Customizable Silent Canopy

The weather-protected silent canopy helps protect the generator set and supports outdoor installation. It includes service-access doors, ventilation openings, exhaust silencing arrangement and a steel base frame with anti-vibration mounting arrangement.

Standard Features

  • Weather-protected steel silent canopy
  • Sound-attenuating insulation material
  • Lockable maintenance-access doors
  • Ventilation and exhaust silencer arrangement
  • Steel base frame and anti-vibration mounts

Customization Options

  • Canopy colour and customer logo
  • Fuel-tank capacity and external fuel connection
  • Cable-entry direction and maintenance layout
  • Special sound-level treatment
  • Hot-climate, cold-climate or coastal options

Overall dimensions, operating weight, fuel-tank capacity and measured sound level depend on the final canopy and accessory configuration. These values are confirmed on the final factory drawing and test report.

SmartGen Control & Protection

The SmartGen digital controller provides generator-set operating control, real-time parameter display, alarm indication and automatic protective shutdown functions. The final controller model is selected according to ATS, remote monitoring and communication requirements.

Monitoring Functions

  • Generator voltage, current, frequency and power display
  • Engine speed, running hours and battery-voltage monitoring
  • Manual, automatic and stop operating modes
  • Start/stop status, alarms and event records

Protection Functions

  • Low oil pressure protection
  • High coolant temperature protection
  • Overspeed and low battery-voltage alarms
  • Over/under voltage and over/under frequency protection
  • Overcurrent and overload protection, subject to breaker selection

60Hz / 220V Electrical Configuration

ItemSpecification
Standard Frequency60Hz
Standard Speed1800 rpm
Standard Voltage220V
Phase3 phase
Prime Output60kW / 75kVA
Rated Current196.8A
Other Voltage OptionsAvailable after confirmation of alternator, controller and engine-generator matching.

Please provide installation country, local voltage, frequency, load type and any motor-starting, UPS or non-linear-load requirements when requesting a quotation.

Applications

  • Commercial buildings and retail sites
  • Workshops and small industrial facilities
  • Farms, irrigation and agricultural facilities
  • Construction and temporary site power
  • Warehouses and logistics facilities
  • Telecom and utility-support installations
  • Institutional and residential backup power
  • 60Hz export projects requiring 220V three-phase supply

Optional Equipment

  • ATS cabinet or integrated ATS control
  • Additional base fuel tank or external fuel connection
  • Battery charger and engine water heater
  • Remote-monitoring module and communication accessories
  • Customer-logo painting and special canopy colour
  • Trailer or mobile-generator arrangement
  • Sound-level upgrade or special exhaust treatment
  • Output breaker and distribution panel
  • Cold-climate, hot-climate or dust-protection enhancement
  • Parallel / synchronizing solution after technical review

Factory Testing & Documentation

Each generator set is checked before shipment according to the approved configuration. The agreed test scope can include visual inspection, engine start/stop checks, alarm and controller checks, voltage/frequency verification, load testing and ATS functional testing when an ATS is included.

Documents Available

  • Generator-set nameplate and specification sheet
  • Engine and alternator identification details
  • Test report with agreed test conditions
  • Operation and maintenance documents

Pre-shipment Confirmation

  • Confirmed voltage, frequency and phase
  • Output rating and breaker configuration
  • Canopy, fuel-system and ATS options
  • Packing list and export documentation

FAQ

What is the rated output of this generator set?

The supplied alternator nameplate is rated at 75kVA, 220V, 60Hz and 0.8 power factor. This corresponds to 60kW rated output. The matching standby rating is 66kW / 82.5kVA.

Is this a 50Hz or 60Hz generator?

This is a 60Hz generator set. The alternator nameplate states 60Hz and 1800 rpm.

Is the alternator a genuine Stamford unit?

The supplied nameplate identifies the alternator as TFW2-50 and does not show a Stamford brand. To keep the product page accurate, it is described as an AVR-controlled TFW2-50 brushless alternator.

Can the silent canopy be customized?

Yes. Canopy colour, logo, fuel-tank arrangement, cable entry, maintenance access, sound-level treatment and environmental options can be customized for the project.

Can an ATS be supplied with this generator?

Yes. An ATS cabinet or integrated ATS control can be supplied after confirming the load, breaker rating, voltage and transfer requirements.

Request a Quote for This 60kW Cummins Generator Set

Send your project requirements to HONGTAI for a confirmed technical configuration and quotation.

  • Required prime and standby power
  • Frequency, voltage, phase and installation country
  • Load type, including motor-starting or sensitive-load requirements
  • Silent canopy, fuel tank, ATS and remote-monitoring requirements
  • Quantity, delivery time and required documents

Request a Technical Quotation

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer visit

Customer visit

Customer visit

Customer visit

Customer visit

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Related products

undefined

undefined

Request Quote

If you have product needs, please contact us in time to get your exclusive offer.