150kW 187.5kVA Cummins QSB6.7-G4 Open Type Diesel Generator with ATS

150kW 187.5kVA Automatic Mains Failure Generator Powered by Cummins QSB6.7-G4 Engine, 400/230V 50Hz, Leroy-Somer Alternator, Open Type, ATS Auto Start/Stop

Share to:

Description

Core Specifications

The HONGTAI 150kW open type diesel generator set is designed for reliable 50Hz standby and prime-power applications. The shown configuration uses a Cummins QSB6.7-G4 diesel engine, a genuine Nidec Leroy-Somer alternator and an Automatic Transfer Switch for automatic mains-failure operation.

ProductHONGTAI 150kW 187.5kVA Cummins Open Type Diesel Generator with ATS
Prime Power150kW / 187.5kVA
Standby Power165kW / 206.25kVA, subject to final alternator and ATS configuration
EngineCummins QSB6.7-G4
Shown AlternatorGenuine Nidec Leroy-Somer TAL-A44-M J6S/4
Alternator OptionsSTAMFORD, Leroy-Somer, Marathon, HONGTAI full-copper brushless alternator or other approved brands
Controller OptionsSmartGen, Deep Sea Electronics (DSE), ComAp, Woodward or other compatible brands
Frequency / Speed50Hz / 1500 rpm
Rated Voltage400/230V
Phase / Wiring3 phase, 4 wire
Power Factor0.8
Rated CurrentApproximately 270.6A at 400V, 150kW, 0.8 power factor
TypeOpen type diesel generator set
Automatic Transfer SwitchIncluded for automatic mains-failure start/stop operation

Automatic power transfer: when mains power fails, the ATS sends a start command to the generator. After generator voltage and frequency stabilize, the ATS transfers the load to generator power. When mains power returns and stabilizes, the ATS transfers the load back to mains power; after the cooling period, the generator stops automatically.

Product Overview

The HONGTAI 150kW / 187.5kVA Cummins open generator set provides dependable automatic backup power for industrial facilities, commercial buildings, data and communication installations, farms, warehouses and critical site-power applications.

This open type configuration provides convenient access for inspection and maintenance. The supplied ATS control system automatically monitors utility power and manages generator start, transfer, retransfer and shutdown, reducing the need for manual intervention during a mains outage.

Cummins QSB6.7-G4 Engine Specifications

ManufacturerDongfeng Cummins Engine Co., Ltd.
Engine ModelQSB6.7-G4
Engine Type4-stroke, in-line, 6-cylinder diesel engine
Displacement6.7L
Bore × Stroke107mm × 124mm
Compression Ratio17.3:1
Cooling SystemWater-cooled
Air IntakeTurbocharged and air-to-air intercooled
Fuel SystemElectronic common-rail fuel system
Starting System24V DC electric start
Rated Speed1500 rpm for 50Hz configuration

Engine Power Data

  • Prime engine power: 168kW at 1500 rpm
  • Standby engine power: 185kW at 1500 rpm
  • Generator-set prime output: 150kW / 187.5kVA
  • Engine-only lubricating-oil capacity: approximately 19.5L
  • Engine-only coolant capacity: approximately 30L

The engine nameplate is the authority for engine data. Final generator-set output depends on selected alternator, ambient condition, altitude, voltage, control system and operating duty.

Alternator Options

The shown configuration uses a genuine Nidec Leroy-Somer alternator. HONGTAI can also configure STAMFORD, Marathon or HONGTAI full-copper brushless alternators according to the project power requirement, voltage, load type and budget.

Shown Alternator BrandNidec Leroy-Somer
Shown Alternator ModelTAL-A44-M J6S/4
50Hz Rated Voltage380V / 400V / 415V
50Hz Rated Speed1500 rpm
50Hz Capacity at 400V200kVA / 160kW, continuous duty at 40°C
EnclosureIP23
Thermal ClassH/H
AVRR120
ExcitationShunt
Power Factor0.8
AltitudeBelow 1000m
Available Brand OptionsSTAMFORD, Leroy-Somer, Marathon, HONGTAI full-copper brushless alternator or other approved brands

Alternator selection: specify the required alternator brand in the RFQ. The exact alternator model is selected according to the final voltage, frequency, output rating, motor-starting requirement, insulation requirement and installation environment.

Open Type Generator Set

The open type generator set is installed on a heavy-duty steel base frame and provides convenient access for routine inspection, maintenance and service. It is suitable for equipment rooms, generator rooms, containers or other installations with appropriate ventilation and exhaust design.

Standard Construction

  • Heavy-duty steel base frame
  • Engine and alternator directly coupled
  • Radiator cooling system with safety guard
  • Anti-vibration mounting arrangement
  • Industrial exhaust silencer arrangement

Installation Considerations

  • Adequate room ventilation and heat rejection
  • Correct exhaust routing and back-pressure control
  • Safe fuel supply and electrical cable routing
  • Access space for maintenance and control operation
  • Foundation and vibration-control arrangements

ATS Automatic Mains Failure System

The Automatic Transfer Switch continuously monitors utility power and manages automatic transfer between mains power and generator power. It is suitable for sites that require unattended backup-power operation.

Automatic Operation Sequence

  • ATS monitors mains voltage and frequency
  • Mains failure triggers generator automatic start after the configured delay
  • After generator output stabilizes, the load transfers to generator power
  • When mains returns and stabilizes, the load transfers back to mains
  • Generator runs through a cooling period and stops automatically

ATS Configuration Options

  • ATS cabinet or integrated changeover solution
  • ATS breaker rating matched to site load
  • Utility and generator source monitoring
  • Manual bypass and maintenance arrangement when specified
  • Remote monitoring or alarm output where required

ATS selection must match the site voltage, phase, neutral arrangement, load current, short-circuit protection and local electrical requirements.

Flexible Control System Options

The generator and ATS system can be configured with different controller brands according to the required operating function, automatic-transfer logic and communication protocol.

Available Controller Brands

  • SmartGen
  • Deep Sea Electronics (DSE)
  • ComAp
  • Woodward
  • Other compatible controller brands on request

Typical Protection Functions

  • Low oil pressure and high coolant temperature protection
  • Overspeed and battery-voltage alarms
  • Over/under voltage and over/under frequency protection
  • Overcurrent and overload protection
  • Generator start failure and emergency-stop protection

50Hz / 400V Electrical Configuration

ItemSpecification
Standard Frequency50Hz
Standard Speed1500 rpm
Standard Voltage400/230V
Phase / Wiring3 phase, 4 wire
Prime Output150kW / 187.5kVA
Approximate Prime Current270.6A at 400V and 0.8 power factor
Power Factor0.8
Voltage Options380/220V, 400/230V, 415/240V or other project-specific voltage

Applications

  • Factories, workshops and industrial facilities
  • Commercial buildings and office facilities
  • Warehouses and logistics centers
  • Farms, irrigation and agricultural facilities
  • Telecommunications and utility-support sites
  • Hospitals and institutional backup-power projects
  • Construction and infrastructure projects
  • Sites requiring automatic mains-failure backup power

Optional Equipment

  • STAMFORD, Leroy-Somer, Marathon or HONGTAI alternator selection
  • SmartGen, DSE, ComAp or Woodward controller selection
  • ATS cabinet, bypass system or special changeover arrangement
  • Extended fuel tank or external fuel connection
  • Battery charger and engine water heater
  • Remote monitoring and communication accessories
  • Output breaker and distribution panel
  • Sound-attenuated canopy or containerized enclosure
  • Cold-climate, high-temperature or dust-protection upgrade
  • Special export packing and documentation

Factory Testing & Documentation

Each generator set is checked before shipment according to the approved configuration. The agreed test scope can include engine start/stop testing, controller and alarm verification, voltage/frequency checks, load testing and ATS functional testing.

Documents Available

  • Generator-set nameplate and final specification sheet
  • Engine, alternator and controller identification details
  • Test report with agreed test conditions
  • Operation and maintenance documents

Pre-shipment Confirmation

  • Confirmed voltage, frequency and power rating
  • Selected alternator and controller brand
  • ATS type, breaker rating and transfer logic
  • Output panel, fuel system and export documents

FAQ

What happens when mains power fails?

The ATS detects the mains failure, starts the generator automatically, transfers the load after generator output stabilizes, and returns the load to mains power once the utility supply recovers and is stable.

Does the generator stop automatically after mains power returns?

Yes. After the ATS retransfers the load to stable mains power, the generator completes its configured cooling period and stops automatically.

Which alternator brands can be selected?

The shown configuration uses a genuine Nidec Leroy-Somer alternator. STAMFORD, Leroy-Somer, Marathon and HONGTAI full-copper brushless alternators are available according to the project.

Which controller brands can be selected?

SmartGen, Deep Sea Electronics, ComAp, Woodward and other compatible control systems can be selected according to ATS and remote-monitoring requirements.

Can this open generator set be installed outdoors?

An open generator set is normally installed in a generator room, container or other protected installation with adequate ventilation and exhaust design. A soundproof canopy or containerized enclosure can be supplied for outdoor use.

Request a Quote for This 150kW Cummins Generator Set

Send your project requirements to HONGTAI for a confirmed generator, ATS and control-system configuration.

  • Required prime and standby power
  • Frequency, voltage, phase and installation country
  • Required alternator brand and controller brand
  • ATS type, load current and automatic-transfer requirements
  • Open type, silent canopy or containerized enclosure requirement

Request a Technical Quotation

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer visit

Customer visit

Customer visit

Customer visit

Customer visit

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Related products

undefined

undefined

Request Quote

If you have product needs, please contact us in time to get your exclusive offer.