The HONGTAI 150kW silent diesel generator set is designed for reliable standby power and suitably specified prime-power applications. It is powered by a Cummins 6CTAA8.3-G2 diesel engine and equipped with a HONGTAI full-copper brushless alternator, digital generator controller and weather-protected sound-attenuated canopy.
| Product | HONGTAI 150kW 187.5kVA Cummins Silent Diesel Generator Set |
|---|---|
| Prime Power | 150kW / 187.5kVA |
| Standby Power | 165kW / 206.25kVA, subject to final alternator and control-panel configuration |
| Engine | Cummins 6CTAA8.3-G2 |
| Standard Alternator | HONGTAI full-copper brushless alternator with AVR |
| Alternator Options | STAMFORD, Leroy-Somer, Marathon or other approved brands |
| Controller Options | SmartGen, Deep Sea Electronics (DSE), ComAp, Woodward or other compatible brands |
| Frequency / Speed | 50Hz / 1500 rpm |
| Rated Voltage | 400/230V |
| Phase / Wiring | 3 phase, 4 wire |
| Power Factor | 0.8 |
| Rated Current | Approximately 270.6A at 400V, 150kW and 0.8 power factor |
| Canopy Type | Weather-protected sound-attenuated silent canopy |
| ATS | Optional automatic transfer switch |
Configuration principle: the published 150kW / 187.5kVA rating is based on 50Hz, 400/230V and 0.8 power factor. Final electrical ratings, alternator model, controller model, ATS rating and enclosure details follow the approved quotation and generator nameplate.
Product Overview
The HONGTAI 150kW silent diesel generator set provides dependable power for facilities that need lower operating noise, weather protection and convenient maintenance access. The sound-attenuated enclosure is suitable for commercial buildings, factories, farms, warehouses, construction projects, telecom sites and other outdoor or noise-sensitive applications.
The standard configuration uses a HONGTAI full-copper brushless alternator. STAMFORD, Leroy-Somer, Marathon and other approved alternator brands can be selected when specified in the order. The canopy colour, exterior design, coating, customer logo, fuel arrangement, cable outlet and selected accessories can be customized.

Cummins 6CTAA8.3-G2 Engine Specifications
| Manufacturer | Dongfeng Cummins Engine Co., Ltd. |
|---|---|
| Engine Model | 6CTAA8.3-G2 |
| CPL | 1786 |
| Engine Type | 4-stroke, in-line, 6-cylinder diesel engine |
| Displacement | 8.3L |
| Cooling System | Water-cooled |
| Air Intake | Turbocharged and aftercooled |
| Net Weight | 637kg |
| Idle Speed | 850 rpm |
| Fuel Rate at Rated HP | 153 mm³/stroke |
Engine Power Data
- Prime power: 163kW at 1500 rpm
- Standby power: 180kW at 1500 rpm
- Prime power: 170kW at 1800 rpm
- Standby power: 187kW at 1800 rpm
- This product is configured as a 50Hz / 1500 rpm generator set.
Engine nameplate values describe engine capacity. Final generator-set output depends on alternator selection, voltage, frequency, ambient conditions, altitude and operating duty.

HONGTAI Full-Copper Brushless Alternator
The standard HONGTAI alternator uses a full-copper winding and brushless excitation system with AVR voltage regulation. It is matched to the generator rating, voltage, frequency and load requirement. International alternator brands can also be supplied when specified in the quotation.
| Standard Brand | HONGTAI |
|---|---|
| Construction | Full-copper winding, brushless synchronous alternator |
| Excitation System | AVR controlled |
| Rated Output | 150kW / 187.5kVA |
| Frequency | 50Hz |
| Voltage | 400/230V |
| Phase / Wiring | 3 phase, 4 wire |
| Power Factor | 0.8 |
| Insulation Class | Class H or according to final alternator specification |
| Protection Class | IP23 or according to final alternator specification |
| Available Upgrades | STAMFORD, Leroy-Somer, Marathon or other approved brands |
Alternator selection: tell HONGTAI the required alternator brand, local voltage, frequency, motor-starting demand, UPS/non-linear load requirement and environmental conditions. The final alternator model is confirmed in the approved technical quotation.
Customizable Silent Canopy
The sound-attenuated canopy is designed to reduce operating noise while protecting the generator set from weather and providing practical service access. The enclosure shown includes acoustic-lined maintenance doors, ventilation openings, an external emergency-stop position and a steel base frame.
Standard Silent Canopy Features
- Weather-protected steel silent canopy
- Acoustic insulation material on maintenance doors
- Lockable maintenance doors and service access
- Ventilation intake and exhaust arrangement
- Industrial exhaust silencer arrangement
- Steel base frame with anti-vibration mounting arrangement
Customization Options
- Canopy colour, paint finish and customer logo
- Exterior structure, doors and maintenance layout
- Fuel-tank capacity or external fuel connection
- Cable-entry direction and output-panel location
- Special noise-control treatment and exhaust arrangement
- Cold-climate, high-temperature or coastal-environment options
Overall dimensions, operating weight, fuel-tank capacity and measured sound level depend on the final canopy, alternator, fuel-system and accessory selection. Confirm these values on the final factory drawing and test documentation.
Flexible Control System Options
The generator set can be equipped with different controller brands and functions according to the required operating mode, ATS requirement, remote-monitoring requirement and project specification.
Available Controller Brands
- SmartGen
- Deep Sea Electronics (DSE)
- ComAp
- Woodward
- Other compatible controller brands on request
Typical Control & Protection
- Generator voltage, current, frequency and power display
- Engine speed, running hours and battery-voltage monitoring
- Manual, automatic and stop operating modes
- Low oil pressure and high coolant-temperature protection
- Over/under voltage, frequency and overload protection
- Generator start-failure and emergency-stop protection
Automatic Transfer Switch (Optional)
An ATS can be supplied for automatic backup-power operation. When utility power fails, the ATS sends a start command to the generator. Once generator voltage and frequency are stable, the load transfers to generator power. When utility power returns and remains stable, the ATS transfers the load back to mains power; after the cooling period, the generator stops automatically.
ATS Functions
- Utility voltage and frequency monitoring
- Automatic generator start after mains failure
- Automatic load transfer to generator power
- Automatic retransfer when mains power recovers
- Automatic generator cool-down and stop
ATS Selection
- ATS cabinet or integrated changeover solution
- Breaker rating matched to site load
- Manual bypass arrangement when specified
- Remote alarm and communication options
- Compatible with selected generator controller
50Hz / 400V Electrical Configuration
| Item | Specification |
|---|---|
| Standard Frequency | 50Hz |
| Standard Speed | 1500 rpm |
| Standard Voltage | 400/230V |
| Phase / Wiring | 3 phase, 4 wire |
| Prime Output | 150kW / 187.5kVA |
| Approximate Prime Current | 270.6A at 400V and 0.8 power factor |
| Power Factor | 0.8 |
| Voltage Options | 380/220V, 400/230V, 415/240V or other project-specific voltage |
| 60Hz Option | Available as a separate engineered configuration; final output and alternator matching must be confirmed before order. |
Please provide installation country, frequency, voltage, phase, load type, motor-starting requirement, UPS load or other non-linear load information before quotation.
Applications
- Factories, workshops and industrial facilities
- Commercial buildings and retail sites
- Warehouses and logistics centers
- Farms, irrigation and agricultural facilities
- Telecommunications and utility-support installations
- Hospitals and institutional backup-power projects
- Construction and infrastructure projects
- Outdoor and noise-sensitive installations
Optional Equipment
- STAMFORD, Leroy-Somer, Marathon or HONGTAI alternator selection
- SmartGen, DSE, ComAp or Woodward controller selection
- ATS cabinet or integrated automatic transfer solution
- Extended base fuel tank or external fuel connection
- Battery charger and engine water heater
- Remote monitoring and communication accessories
- Output breaker and distribution panel
- Custom canopy colour, logo and coating
- Special sound-level or exhaust-treatment upgrade
- Cold-climate, hot-climate or dust-protection enhancement
Factory Testing & Documentation
Each generator set is checked before shipment according to the approved technical configuration. The agreed test scope can include visual inspection, engine start/stop checks, controller and alarm verification, voltage/frequency checks, load testing and ATS functional testing when ATS is included.
Documents Available
- Generator-set nameplate and final specification sheet
- Engine, alternator and controller identification details
- Test report with agreed test conditions
- Operation and maintenance documents
Pre-shipment Confirmation
- Confirmed voltage, frequency and output rating
- Selected alternator and controller brand
- Silent canopy, fuel-system and ATS requirements
- Packing list and agreed export documentation
FAQ
What is the standard output of this generator set?
The standard 50Hz configuration is rated at 150kW / 187.5kVA, 400/230V, 3 phase, 4 wire, with a power factor of 0.8.
Which alternator is supplied as standard?
The standard configuration uses a HONGTAI full-copper brushless alternator with AVR voltage regulation. STAMFORD, Leroy-Somer, Marathon and other approved brands can be selected as upgrades.
Can the silent canopy be customized?
Yes. Canopy colour, exterior shape, coating, customer logo, maintenance doors, fuel system, cable outlet and selected noise-control features can be customized for the project.
Can this generator be supplied with ATS?
Yes. An ATS can be supplied to automatically start the generator after utility power failure, transfer the load to generator power, return the load to mains power after recovery and stop the generator after its cooling period.
Can the generator be supplied in 60Hz?
Yes, a 60Hz version can be engineered. Frequency changes engine speed, alternator selection and output rating, so the final 60Hz configuration must be confirmed before quotation.
Request a Quote for This 150kW Cummins Silent Generator Set
Send your project requirements to HONGTAI for a confirmed generator, alternator, canopy and control-system configuration.
- Required prime and standby power
- Frequency, voltage, phase and installation country
- Required alternator and controller brand
- ATS, fuel tank, remote monitoring and output-panel requirements
- Canopy colour, logo, sound-level and environmental requirements
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer visit
Customer visit
Customer visit
Factory
Factory
Factory
Factory
Factory
Factory
Factory
Factory
Factory
Related products
undefined