1. Core Specifications
| Generator Set Type | Open Type Diesel Generator Set |
|---|---|
| Prime Power | 1200kW / 1500kVA |
| Standby Power | 1320kW / 1650kVA |
| Engine Brand | Weichai Baudouin |
| Engine Model | 12M33D1320E200 |
| Engine Rated Power | 1200kW prime / 1320kW standby at 1500rpm, according to supplied engine nameplate |
| Alternator | HONGTAI Full-Copper Brushless Alternator |
| Alternator Options | Stamford, Leroy-Somer, Marathon, HONGTAI or customer-approved brand |
| Controller | SmartGen Digital Generator Controller |
| Controller Options | SmartGen, Deep Sea, ComAp, Woodward or customer-approved brand |
| Frequency / Speed | 50Hz / 1500rpm standard; 60Hz / 1800rpm available on request |
| Voltage / Phase | 400/230V, 3 Phase, 4 Wire standard; customized voltage available |
| Power Factor | 0.8 standard |
| Starting System | 24V DC electric starting system |
| Fuel Tank | Base fuel tank or external fuel tank, subject to required operating hours |
| ATS | Optional automatic transfer switch for mains failure and mains recovery operation |
2. Product Overview
The HONGTAI 1200kW open type diesel generator set is designed for large industrial, commercial and infrastructure power applications. It is powered by a Weichai Baudouin 12M33D1320E200 diesel engine and matched with a HONGTAI full-copper brushless alternator.
This 1500kVA generator set is suitable for standby power, prime power and continuous project-based power supply where a high-output, serviceable and configurable generating system is required. The open type structure provides convenient maintenance access and is recommended for installation in a generator room, power station building or other protected installation area.
Frequency, voltage, alternator brand, controller brand, fuel tank capacity, ATS system, synchronization function, remote monitoring and enclosure solution can be configured according to the project requirement.
3. Product Photos


4. Engine Specifications
| Engine Brand | Weichai Baudouin |
|---|---|
| Engine Model | 12M33D1320E200 |
| Engine Type | Heavy-duty generating diesel engine |
| Prime Engine Power | 1200kW at 1500rpm |
| Standby Engine Power | 1320kW at 1500rpm |
| Cooling Method | Water-cooled radiator system |
| Starting Method | 24V DC electric start |
| Governor | Configured to maintain stable generator frequency under varying load conditions |
| Air Intake / Exhaust | Configured according to engine package and installation requirements |
| Fuel Consumption | To be confirmed according to final load level, operating condition, frequency and technical configuration |
5. Alternator Specifications
Standard Alternator
HONGTAI Full-Copper Brushless Alternator
- Brushless synchronous AC alternator
- 100% copper winding
- AVR automatic voltage regulation
- Three-phase, four-wire output
- Insulation class and protection class matched to final configuration
- Designed for stable voltage output and industrial generator applications
Alternator Brand Options
- Stamford alternator
- Leroy-Somer alternator
- Marathon alternator
- HONGTAI full-copper brushless alternator
- Customer-specified or approved alternator brand
- Final alternator model is selected according to power, voltage, frequency and load characteristics
6. Open Type Configuration
Open Skid Structure
- Heavy-duty steel base frame
- Engine, alternator, radiator and control system assembled on one common base
- Anti-vibration mounts between engine-alternator assembly and base frame
- Convenient access for inspection, servicing and maintenance
- Suitable for indoor generator rooms and protected power stations
Optional Protection Solution
- Weather-resistant rainproof canopy available
- Silent canopy available for projects requiring lower operating noise
- Containerized generator power station available
- External fuel tank and fuel transfer system available
- Air intake, exhaust silencer and ventilation design can be matched to site conditions
7. Control System and Protection
| Standard Controller | SmartGen digital generator controller |
|---|---|
| Operating Modes | Manual start, automatic start and remote start capability depending on selected configuration |
| Monitoring Functions | Generator voltage, current, frequency, power, engine speed, oil pressure, coolant temperature, battery voltage and running hours |
| Engine Protections | Low oil pressure, high coolant temperature, overspeed, start failure and low battery voltage protection |
| Electrical Protections | Overload, overcurrent, short circuit, abnormal voltage and abnormal frequency protection, depending on selected breaker and controller configuration |
| ATS Function | Optional ATS automatically starts the generator when mains power fails and transfers the load after power is stable |
| Remote Monitoring | Optional GSM, Ethernet, cloud platform or remote monitoring solution |
| Advanced Options | Synchronization panel, load sharing panel, parallel operation and power management system available |
8. 50Hz / 60Hz and Voltage Options
50Hz Standard Configuration
- 1500rpm operating speed
- 400/230V, 3 Phase, 4 Wire commonly supplied
- 380V, 400V and 415V available according to destination market
- Suitable for many industrial and commercial power systems
60Hz and Custom Voltage
- 60Hz / 1800rpm configuration available on request
- 208V, 220V, 240V, 440V, 460V and 480V available subject to technical confirmation
- Voltage, frequency, phase arrangement and outlet configuration can be customized
- Please provide the installation country and local electrical requirement when requesting a quotation
9. Applications
Typical Applications
- Industrial factories and manufacturing plants
- Data centers and telecommunications facilities
- Commercial buildings and large property projects
- Hospitals, public facilities and emergency power systems
- Mining, oilfield and remote construction projects
Power Supply Solutions
- Standby power during mains power failure
- Prime power for areas with unstable utility supply
- Continuous operation for selected project requirements
- Parallel generator power stations
- Large-capacity temporary site power supply
10. Optional Equipment
| Alternator Options | Stamford, Leroy-Somer, Marathon, HONGTAI or customer-approved brand |
|---|---|
| Controller Options | SmartGen, Deep Sea, ComAp, Woodward or customer-approved brand |
| Automatic Transfer Switch | ATS cabinet for automatic mains failure and mains recovery operation |
| Fuel System | Extended base tank, external daily fuel tank, bulk fuel tank and automatic fuel transfer system |
| Canopy Options | Rainproof canopy, silent canopy, containerized power station or customized enclosure |
| Exhaust System | Industrial silencer, residential silencer, critical silencer or customized exhaust piping |
| Parallel System | Synchronization panel, load sharing panel and multi-generator parallel operation system |
| Remote System | Remote monitoring, remote start/stop, GSM module, Ethernet connection or cloud platform |
| Output System | Generator breaker cabinet, cable outlet box, busbar system and customized power distribution cabinet |
11. Factory Testing
Each HONGTAI diesel generator set is inspected before delivery. The final testing scope is matched to the confirmed technical configuration and project requirement.
- Appearance, assembly and wiring inspection
- Engine starting and shutdown test
- Voltage, frequency and phase sequence verification
- Controller monitoring and protection function test
- Breaker, ATS or synchronization system test when supplied
- Load test according to agreed testing requirement
- Factory photos, videos and test documents available according to order requirements
12. FAQ
Request a Quote for This 1200kW Weichai Baudouin Generator Set
Send your project requirements to HONGTAI for a confirmed technical configuration and quotation.
- Required prime and standby power
- Frequency, voltage, phase and installation country
- Load type, including motor-starting, nonlinear-load or sensitive-load requirements
- Alternator brand, controller brand, breaker and ATS requirements
- Fuel tank capacity, canopy, container and ventilation requirements
- Parallel operation, remote monitoring and required documents
- Quantity, delivery schedule and destination port
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer shipment
Customer visit
Customer visit
Customer visit
Factory
Factory
Factory
Factory
Factory
Factory
Factory
Factory
Factory
Related products