750kW 937.5kVA Cummins KTA38-G1 Open Diesel Generator Set (60Hz Standby)

675kW Prime / 750kW Standby | Cummins KTA38-G1 Engine | HONGTAI Full-Copper Brushless Alternator | 480V 60Hz, 3 Phase

Share to:

Description

Core Specifications

Generator Set TypeOpen Type / Open Skid Diesel Generator Set
Standby Power750kW / 937.5kVA
Prime Power675kW / 843.75kVA
Engine BrandCummins
Engine ModelKTA38-G1
AlternatorHONGTAI Full-Copper Brushless Alternator
Frequency / Speed60Hz / 1800rpm
Voltage480V, 3 Phase, 4 Wire
Power Factor0.8
ControllerSmartGen Standard; Deep Sea, ComAp, Woodward and other brands optional
ATSOptional for automatic mains failure start and transfer
InstallationIndoor installation or installation in a plant room / container / customer-built enclosure

Product Overview

The HONGTAI 750kW open type diesel generator set is designed for large standby power applications. Powered by a Cummins KTA38-G1 diesel engine, this generator set delivers 750kW / 937.5kVA standby power at 60Hz and is suitable for projects requiring a high-capacity three-phase power supply.

The standard configuration includes a HONGTAI full-copper brushless alternator, industrial radiator, steel base frame, SmartGen controller and circuit breaker. Stamford, Leroy-Somer, Marathon and other alternator brands are available according to customer requirements.

Rating note: This page is based on a 60Hz / 1800rpm configuration. If you need 50Hz / 1500rpm, please request a separate technical quotation because output power and alternator selection will be different.

Product Photos

Cummins Engine Specifications

Engine BrandCummins
Engine ModelKTA38-G1
Engine TypeV-type 12-cylinder, 4-cycle diesel engine
Displacement38L class engine
Air Intake SystemTurbocharged and aftercooled
Fuel SystemCummins PT fuel system with direct injection
Cooling SystemWater-cooled with industrial radiator
Starting System24V DC electric start
Rated Speed1800rpm for 60Hz configuration
GovernorElectronic governor configuration, subject to final engine supply specification
Fuel FilterDual spin-on fuel filters with water separator
Lubrication FilterSpin-on full-flow lubricating oil filter

Alternator Specifications

Standard Alternator

  • HONGTAI full-copper brushless synchronous alternator
  • 100% copper winding
  • AVR automatic voltage regulation
  • 3 phase, 4 wire output
  • Suitable for 60Hz, 480V and other international voltage options
  • Alternator capacity selected to match the final generator duty rating

Optional Alternator Brands

  • Stamford alternator
  • Leroy-Somer alternator
  • Marathon alternator
  • Other customer-specified alternator brands
  • PMG excitation and special voltage regulation configurations available

Open Skid Base Frame and Installation

Open Type Features

  • Heavy-duty fabricated steel base frame
  • Anti-vibration mounts between engine, alternator and base frame
  • Industrial radiator cooling system
  • Flexible exhaust connection and industrial exhaust silencer
  • Integrated lifting points for handling and installation
  • Suitable for installation in a plant room, generator room or container

Optional Installation Solutions

  • Weatherproof canopy available
  • Silent canopy available for noise-sensitive projects
  • Containerized generator solution available
  • Base fuel tank or external day tank available
  • Exhaust piping, ventilation and fuel system can be designed for the project

Control System and Protection

Standard ControllerSmartGen generator set controller
Optional Controller BrandsDeep Sea, ComAp, Woodward and other customer-specified brands
Operating ModesManual start, automatic start and remote start configuration available
Engine ProtectionLow oil pressure, high coolant temperature, overspeed, low fuel level and start failure protection
Electrical ProtectionOverload, short circuit, over/under voltage and over/under frequency protection
ATS FunctionOptional ATS cabinet for automatic start and transfer when mains power fails
Remote MonitoringOptional remote monitoring module, communication interface and alarm output

Voltage and Frequency Options

60Hz Configuration

  • 1800rpm
  • 480V / 277V commonly supplied
  • 220V, 440V, 460V and 480V available
  • 3 phase, 4 wire output
  • Standby power: 750kW / 937.5kVA
  • Prime power: 675kW / 843.75kVA

50Hz Configuration

  • 1500rpm
  • 380V, 400V and 415V available
  • 3 phase, 4 wire output
  • Power rating requires separate confirmation
  • Alternator, radiator and controller settings will be matched to 50Hz operation

Applications

  • Large factories and industrial production facilities
  • Commercial buildings, hotels and office complexes
  • Hospitals, data rooms and critical backup power systems
  • Large construction and infrastructure projects
  • Mining, oil and gas field operations
  • Warehouses and logistics centers
  • Remote industrial sites and utility support
  • Power backup for areas with unstable mains supply

Optional Equipment

  • Automatic transfer switch (ATS) cabinet
  • Manual transfer switch (MTS) cabinet
  • Extended base fuel tank or external fuel tank
  • Stamford, Leroy-Somer or Marathon alternator
  • Deep Sea, ComAp, Woodward or other controller brands
  • Remote monitoring and GSM / Ethernet communication module
  • Battery charger and jacket water heater
  • Fuel-water separator and additional fuel filtration
  • Silent canopy or containerized enclosure
  • Customized outlet cabinet, breaker, busbar and cable entry arrangement

Factory Testing

Each HONGTAI generator set is assembled and inspected before delivery. Standard inspection includes appearance inspection, wiring inspection, starting test, controller function test, voltage and frequency check, protection function check and load test according to the agreed order requirement.

Test photos, videos, factory test records, packing photos and shipping details can be provided for customer confirmation before delivery when required.

Frequently Asked Questions

Is this a 750kW generator set?
Yes. This page describes a 750kW / 937.5kVA standby generator set at 60Hz / 1800rpm. Its prime power configuration is 675kW / 843.75kVA.
Can I use this generator at 50Hz?
Yes, a 50Hz version can be supplied. However, 50Hz output power is different from the 60Hz 750kW configuration, so please request a separate technical quotation.
Can I select Stamford or Leroy-Somer alternator?
Yes. The standard configuration is a HONGTAI full-copper brushless alternator. Stamford, Leroy-Somer, Marathon and other brands are available as options.
Can it start automatically when mains power fails?
Yes. With an optional ATS cabinet and automatic controller configuration, the generator can automatically start and transfer the load after mains power failure.

Request a Technical Quotation

Please send your required voltage, frequency, operating location, load type, expected running hours and ATS requirement. HONGTAI will recommend the suitable KTA38-G1 open type generator configuration.

Get a Quote

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer shipment

Customer visit

Customer visit

Customer visit

Customer visit

Customer visit

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Factory

Related products

undefined

undefined

Request Quote

If you have product needs, please contact us in time to get your exclusive offer.